Passing the Cisco 300-615 exam on the first try will help you get the specialist- and professional-level certificates as well as demonstrate to the current or future employer that you are a specialist in the data center solutions field and worthy of the desired position. Thus, the roles that you can choose from include a Data Center Engineering Telecom Manager, a Data Center Systems Administrator, an Infrastructure Manager, a Data Center Technician, and a Data Center VMware Engineer. If you are thinking about what income to expect, you can imagine a range of $39,000-145,000 per year, depending on your title.


Difficulty in writing 300-615 Exam

Cisco 300-615: Troubleshooting Cisco Data Center Infrastructure is the most powerful certification that candidates can have on their resume. But for this, they will have to pass 300-615 questions. Cisco 300-615: Troubleshooting Cisco Data Center Infrastructure Exam is a challenging exam to pass this exam candidates will have to work hard with the help of right focus and preparation material passing this exam is an achievable goal.ITPassLeader help candidates by providing the most relevant and updated 300-615 dumps. Furthermore, We also provide the 300-615 practice test that will be much beneficial in the preparation. ITPassLeader aims to provide the best 300-615 dumps that is verified by the Cisco experts. If candidates feel any doubt in the 300-615 practice exams then our team is always there to help them. 300-615 dumps are the perfect way to prepare 300-615 exam with good grades in the just first attempt. So, candidates want instant success in the 300-615 exam with quality 300-615 training material then ITPassLeader is the best option for them because our management is well trained in it and we update each question of all exams on a regular basis after consulting recent updates with our Cisco certified professionals.

 

NEW QUESTION 53
An engineer discovers that an NPV/NPIV uplink experiences a heavy load and plans to add more uplinks.
What occurs when the new uplinks are added to the uplink?

  • A. Paths must be defined before new connections use the new uplinks.
  • B. Only new connections automatically use the new uplinks.
  • C. New and existing connections automatically use the new uplinks.
  • D. All connections must be reset before the new uplinks are used.

Answer: C

Explanation:
Section: Storage Network

 

NEW QUESTION 54
A mission-critical server is connected to site A. Connectivity to this server is lost from site B because the MAC route is missing in the OTV VDC of the Nexus 7000 in site B due to MAC aging. Which action allows the flooding of the unknown unicast MAC on the Nexus 7000 in the OTV VDC?

  • A. Use route-map to advertise this MAC statically and redistribute with ISIS.
  • B. Use the otv flood mac <> command to selectively flood traffic for a given MAC.
  • C. Use the otv isis bfd <> command to configure BFD protocol.
  • D. Unknown unicast flooding is not allowed.

Answer: B

 

NEW QUESTION 55
Refer to the exhibit.

An engineer is performing a health check on ACI. Which statement about interface Ethernet 1/11 is true?

  • A. "out-of-service" indicates that no service graph is in use for this interface.
  • B. The interface policy is misconfigured.
  • C. The interface is working correctly and fully operational, but it is not in use.
  • D. "out-of-service" is the default interface status in ACI.

Answer: B

 

NEW QUESTION 56
An engineer attempts to register Cisco UCS Manager to Cisco UCS Central, but the registration fails. The engineer can ping Cisco UCS Central from UCS Manager. Which two actions must the engineer attempt to resolve the problem? (Choose two.)

  • A. Synchronize the date and time to NTP for Cisco UCS Central and the Cisco UCS domains.
  • B. Allow port 443 between Cisco UCS Manager and Cisco UCS Central.
  • C. Apply the UCS Central license to UCS Central.
  • D. Place Cisco UCS Manager on the same subnet as Cisco UCS Central.
  • E. Allow port 9443 between Cisco UCS Manager and Cisco UCS Central.

Answer: A,B

Explanation:
Section: Compute Platforms

 

NEW QUESTION 57
Refer to the exhibit.

A web browser displays a "not secure" warning message when accessing the web interface of Cisco UCS Manager. Which action resolves the issue?

  • A. Use a supported web browser.
  • B. Use the correct TCP port for HTTPS.
  • C. Load third-party certificate to UCS Manager.
  • D. Use a supported version of UCS Manager.

Answer: C

 

NEW QUESTION 58
Refer to the exhibit.

Cisco UCS Manager is being upgraded using the Auto Install feature, but the FSM fails. Which action resolves the issue?

  • A. Acknowledge the primary fabric interconnect.
  • B. Remove the service pack from the subordinate fabric interconnect.
  • C. Clear the startup version of the default infrastructure pack.
  • D. Upgrade the firmware of the infrastructure firmware by using the force option.

Answer: C

 

NEW QUESTION 59
Refer to the exhibit.

After a failover occurs, which two actions must be performed on Switch-B to manually preempt the operational primary role back to Switch-A? (Choose two.)

  • A. Configure the local vPC role priority to have the same value as Switch-A.
  • B. Disable and then re-enable the vPC peer link.
  • C. Configure the local vPC role priority to have a lower value than Switch-A.
  • D. Disable and then re-enable the vPC peer-keepalive link.
  • E. Configure the local vPC role priority to have a higher value than Switch-A.

Answer: B,E

 

NEW QUESTION 60
Refer to the exhibit.

During implementation of a Cisco UCS C-Series Server, an engineer receives the status that is shown in the exhibit. Which action resolves the issue.

  • A. Insert an SD card into SLOT-2
  • B. Configure the RAID that is associated with the card.
  • C. Reconfigure the Drive Type from "Removable" to "Non-Removable"
  • D. Set SLOT-1 Sync Mode to "Auto"

Answer: C

 

NEW QUESTION 61
Refer to the exhibit.

Interface fc1/5 is offline. Which action should be taken to troubleshoot the issue?

  • A. Update the FLOGI database to contain the FLOGI entries for interface fc1/5 in VSAN 100.
  • B. Configure the upstream ports and the server ports to be in VSAN 100.
  • C. Update the FCNs database to contain names for VSAN 100.
  • D. Activate the correct zoneset for VSAN 100.

Answer: B

 

NEW QUESTION 62
The external routes fail to propagate to leaf switches in Cisco ACI fabric Which two actions resolve the issue?
(Choose two.)

  • A. Specify the spine nodes as route reflectors
  • B. Configure an MP-BGP area.
  • C. Associate the correct contract to the L30ut.
  • D. Assign an MP-BGP AS number to the fabric.
  • E. Enable the VTEP pool in the fabric

Answer: A,D

 

NEW QUESTION 63
Refer to the exhibit.

A network engineer configures an EEM script to get a syslog notification after a configuration change. This message appears when the engineer must make a new configuration to this switch. Which configuration did the engineer neglect to apply in the script for it to function properly?

  • A. event policy-default count 1 time 100
  • B. event syslog occurs 10
  • C. action 2.0 event-default
  • D. event cli match 'configure terminal'

Answer: C

 

NEW QUESTION 64
Refer to the exhibit.

An engineer is troubleshooting why user1, user2, and user3 from group STORAGE- ADMINISTRATOR in Microsoft Active Directory cannot log in to the Cisco MDS SSH CLI. Which action resolves the issue?

  • A. Include specific users into MDS role configuration.
  • B. Configure SSH logins on Cisco MDS switch.
  • C. Integrate Cisco MDS with Microsoft Active Directory.
  • D. Configure the role name to match the group name on Microsoft Active Directory.

Answer: D

 

NEW QUESTION 65
DRAG DROP
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all options are used.
Select and Place:

Answer:

Explanation:

Section: Compute Platforms

 

NEW QUESTION 66
An engineer is troubleshooting issues in Cisco UCS Director. Drag and drop the possible causes from the left onto the correct issues on the right.

Answer:

Explanation:

 

NEW QUESTION 67
An engineer must upgrade all components in a Cisco UCS domain to the same package version, but the upgrade process fails to complete. Which set of Auto Install actions resolves the problem?

  • A. Install Server Firmware, then Install Infrastructure Firmware
  • B. Install infrastructure Firmware, then Install Hypervisor Firmware.
  • C. Install Hypervisor Firmware, then Install Infrastructure Firmware
  • D. Install Infrastructure Firmware, then Install Server Firmware.

Answer: D

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-5/b_GUI_Firmware_Ma

 

NEW QUESTION 68
Cisco Unified Computing System Manager raises a critical error message that indicates that the system has overlapping Ethernet and FCoE VLANs. All of the Ethernet traffic on the overlapping VLANs drops. Which action resolves the issue?

  • A. Modify the VLAN assignment to vNICs.
  • B. Set the FCoE VLAN as the native VLAN on server uplinks.
  • C. Change the PIN groups on the vHBAs.
  • D. Modify the FCoE VLAN.

Answer: A

Explanation:
Section: Compute Platforms

 

NEW QUESTION 69
An engineer is troubleshooting issues in Cisco UCS Director. Drag and drop the possible causes from the left onto the correct issues on the right.

Answer:

Explanation:

 

NEW QUESTION 70
An engineer must configure Linux hosts that are deployed on Cisco UCS B-Series Servers to boot from SAN.
The SAN boot policy is configured in Cisco UCS Manager, and the boot order is verified to be set as expected.
However, the Linux hosts fail to boot. Which action resolves the issue?

  • A. Remove all of the local storage that is installed.
  • B. Delete and reconfigure the pWWN of the SAN boot target.
  • C. Delete and reconfigure the boot LUN.
  • D. Remove all of the ISO images that are mounted as a virtual CD-ROM.

Answer: A

Explanation:
Section: Storage Network
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/cli/config/guide/2-2/ b_UCSM_CLI_Configuration_Guide_2_2/configuring_server_boot.pdf page 5

 

NEW QUESTION 71
Cisco UCS Manager raises a critical error message that indicates that the system has overlapping Ethernet and FCoE VLANs. All of the Ethernet traffic on the overlapping VLANs drops. Which action resolves the issue?

  • A. Modify the VLAN assignment to vNICs.
  • B. Set the FCoE VLAN as the native VLAN on server uplinks.
  • C. Change the PIN groups on the vHBAs.
  • D. Modify the FCoE VLAN.

Answer: A

Explanation:
Section: Compute Platforms

 

NEW QUESTION 72
Refer to the exhibit.

Sw1 and Sw2 are two Cisco Nexus 9000 Series Switches that run Cisco NX-OS. They are VTEPs in the same vPC domain. Which statement describes what happens in this scenario?

  • A. Sw1 performs the VxLAN multicast encapsulation and decapsulation for all traffic associated with the VxLAN VNIs.
  • B. Sw1 and switch 2 perform the VxLAN multicast encapsulation and decapsulation for all traffic associated with the VxLAN VNIs, depending on the hashing.
  • C. Sw1 drops all traffic because there is no (S, G) OIF list to encapsulate VXLAN multicast packets and send them out to the underlay network through the uplink interfaces.
  • D. Sw2 did not send an IP PIM register to the rendezvous point for the multicast group of the VXLAN VNI.

Answer: A

 

NEW QUESTION 73
An engineer must configure Linux hosts that are deployed on Cisco UCS B-Series Servers to boot from SAN. The SAN boot policy is configured in Cisco UCS Manager, and the boot order is verified to be set as expected However, the Linux hosts fail to boot. Which action resolves the issue?

  • A. Remove all of the local storage that is installed
  • B. Delete and reconfigure the pWWN of the SAN boot target
  • C. Remove all of the ISO images that are mounted as a virtual CD-ROM
  • D. Delete and reconfigure the boot LUN

Answer: A

 

NEW QUESTION 74
Refer to the exhibit.

An engineer is configuring boot from iSCSI on a Cisco UCS B-Series Blade Server, but the LUN fails to mount. Which action resolves the issue?

  • A. Set a connection timeout value of 250 in the iSCSI Adapter Policy.
  • B. Statically configure the target information in the Boot Policy.
  • C. Configure a QoS policy on the vNIC.
  • D. Configure an MTU size of 9000 on the appliance port.

Answer: B

 

NEW QUESTION 75
......